Determine the necessary mass, volume, or concentration for preparing a solution.
Synonyms | 2-METHYLPENTANE | Isohexane | 107-83-5 | Pentane, 2-methyl- | 73513-42-5 | 2-Methyl pentane | 1,1-Dimethylbutane | Hexanes | 2-Methyl-pentane | 64742-49-0 | Methyl pentane | SOLVENT DEGREASER | 2-Methylpentan | 49IB0U6MLD | 43133-95-5 | DTXSID4029143 | CHEBI:88374 | NSC-66496 | Dimethylprop |
---|---|
Specifications & Purity | analytical standard, ≥99.5%(GC) |
Shipped In | Normal |
Grade | analytical standard |
Mechanism of Action | Action Type | target ID | Target Name | Target Type | Target Organism | Binding Site Name | References |
---|
IUPAC Name | 2-methylpentane |
---|---|
INCHI | InChI=1S/C6H14/c1-4-5-6(2)3/h6H,4-5H2,1-3H3 |
InChi Key | AFABGHUZZDYHJO-UHFFFAOYSA-N |
Canonical SMILES | CCCC(C)C |
Isomeric SMILES | CCCC(C)C |
WGK Germany | 2 |
RTECS | SA2985000 |
PubChem CID | 7892 |
UN Number | 1208 |
Packing Group | II |
Molecular Weight | 86.17 |
Beilstein | 1730735 |
Reaxy-Rn | 1730735 |
Enter Lot Number to search for COA:
Find and download the COA for your product by matching the lot number on the packaging.
Lot Number | Certificate Type | Date | Item |
---|---|---|---|
K2111648 | Certificate of Analysis | Aug 02, 2023 | M105778 |
Solubility | Insoluble in water, soluble in most organic solvents such as ethanol, ether, benzene, etc. |
---|---|
Refractive Index | 1.37-1.372 |
Flash Point(°F) | -9.4℉ |
Flash Point(°C) | -23 ℃ |
Boil Point(°C) | 62°C |
Melt Point(°C) | -154°C |
Pictogram(s) | GHS08, GHS09, GHS07, GHS02 |
---|---|
Signal | Danger |
Hazard Statements | H315:Causes skin irritation H411:Toxic to aquatic life with long lasting effects H225:Highly Flammable liquid and vapor H336:May cause drowsiness or dizziness H304:May be fatal if swallowed and enters airways |
Precautionary Statements | P261:Avoid breathing dust/fume/gas/mist/vapors/spray. P273:Avoid release to the environment. P280:Wear protective gloves/protective clothing/eye protection/face protection. P301+P310:IF SWALLOWED: Immediately call a POISON CENTER/doctor/... P370+P378:In case of fire: Use ... to extinguish. P210:Keep away from heat, hot surface, sparks, open flames and other ignition sources. - No smoking. P405:Store locked up. P501:Dispose of contents/container to ... P233:Keep container tightly closed. P240:Ground/bond container and receiving equipment. P264:Wash hands [and …] thoroughly after handling. P403+P235:Store in a well-ventilated place. Keep cool. P303+P361+P353:IF ON SKIN (or hair): Take off Immediately all contaminated clothing. Rinse SKIN with water [or shower]. P271:Use only outdoors or in a well-ventilated area. P241:Use explosion-proof [electrical/ventilating/lighting/.../] equipment. P331:Do NOT induce vomiting. P403+P233:Store in a well-ventilated place. Keep container tightly closed. P332+P313:IF SKIN irritation occurs: Get medical advice/attention. P391:Collect spillage. P242:Use only non-sparking tools. P243:Take precautionary measures against static discharge. P304+P340+P312: IF INHALED: Remove person to fresh air and keep comfortable for breathing.Call a POISON CENTER or doctor. if you feel unwell. |
WGK Germany | 2 |
RTECS | SA2985000 |
Reaxy-Rn | 1730735 |
Class | 3 |
1. Yin Xie, Xiaowei Xu, Yan Cui, Liang Qiao, Kebin Chi, Dejun Shi, Yang Bai, Zhijie Wu, Shengbao He. (2023) Colloidal chemistry of MAPbI3 perovskite ink using 2-methoxyethanol as the solvent. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 677 (7): (132406). [PMID:24207024] [10.1016/j.colsurfa.2023.132406] |
2. Ziqi Sun, Meiling Qi. (2022) High separation performance of carbon dioxide-based poly(ether-carbonate) copolymer for gas chromatographic analyses. JOURNAL OF CHROMATOGRAPHY A, 1682 (463493). [PMID:36166885] [10.1016/j.chroma.2022.463493] |
3. Ruijuan Duan, Meiling Qi. (2021) Amphiphilic triblock copolymer as the gas chromatographic stationary phase with high-resolution performance towards a wide range of isomers and the components of lemon essential oil. JOURNAL OF CHROMATOGRAPHY A, 1658 (462611). [PMID:34666270] [10.1016/j.chroma.2021.462611] |
4. Lele Jin, Wenzhi Li, Qiying Liu, Longlong Ma, Chao Hu, Ajibola T. Ogunbiyi, Mingwei Wu, Qi Zhang. (2020) High performance of Mo-promoted Ir/SiO2 catalysts combined with HZSM-5 toward the conversion of cellulose to C5/C6 alkanes. BIORESOURCE TECHNOLOGY, 297 (122492). [PMID:31796376] [10.1016/j.biortech.2019.122492] |
5. Lele Jin, Wenzhi Li, Qiying Liu, Longlong Ma, Song Li, Yang Liu, Baikai Zhang, Qi Zhang. (2019) Catalytic conversion of cellulose to C5/C6 alkanes over Ir-VOx/SO2 combined with HZSM-5 in n-dodecane/water system. FUEL PROCESSING TECHNOLOGY, 196 (106161). [PMID:] [10.1016/j.fuproc.2019.106161] |
6. Yuan-Yuan Cui, Huan Yao, Cheng-Xiong Yang, Xiu-Ping Yan. (2019) In situ fabrication of microporous organic network coated capillary column for high resolution gas chromatographic separation of hydrocarbons. ELECTROPHORESIS, 40 (16-17): (2186-2192). [PMID:30942493] [10.1002/elps.201800540] |
7. Lin Fan, Xiu-Ping Yan. (2012) Evaluation of isostructural metal–organic frameworks coated capillary columns for the gas chromatographic separation of alkane isomers. TALANTA, 99 (944). [PMID:22967647] [10.1016/j.talanta.2012.07.063] |
8. Xue Xiong,Meiling Qi. (2018-08-14) Hexagonal boron nitride stationary phase for gas chromatography.. Journal of chromatography. A, 1567 (191-197). [PMID:30100014] |
9. Qian Yuan,Meiling Qi. (2020-04-19) Triptycene-based dicationic guanidinium ionic liquid: A novel stationary phase of high selectivity towards a wide range of positional and structural isomers.. Journal of chromatography. A, 1621 (461084-461084). [PMID:32303345] |
1. Yin Xie, Xiaowei Xu, Yan Cui, Liang Qiao, Kebin Chi, Dejun Shi, Yang Bai, Zhijie Wu, Shengbao He. (2023) Colloidal chemistry of MAPbI3 perovskite ink using 2-methoxyethanol as the solvent. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 677 (7): (132406). [PMID:24207024] [10.1016/j.colsurfa.2023.132406] |
2. Ziqi Sun, Meiling Qi. (2022) High separation performance of carbon dioxide-based poly(ether-carbonate) copolymer for gas chromatographic analyses. JOURNAL OF CHROMATOGRAPHY A, 1682 (463493). [PMID:36166885] [10.1016/j.chroma.2022.463493] |
3. Ruijuan Duan, Meiling Qi. (2021) Amphiphilic triblock copolymer as the gas chromatographic stationary phase with high-resolution performance towards a wide range of isomers and the components of lemon essential oil. JOURNAL OF CHROMATOGRAPHY A, 1658 (462611). [PMID:34666270] [10.1016/j.chroma.2021.462611] |
4. Lele Jin, Wenzhi Li, Qiying Liu, Longlong Ma, Chao Hu, Ajibola T. Ogunbiyi, Mingwei Wu, Qi Zhang. (2020) High performance of Mo-promoted Ir/SiO2 catalysts combined with HZSM-5 toward the conversion of cellulose to C5/C6 alkanes. BIORESOURCE TECHNOLOGY, 297 (122492). [PMID:31796376] [10.1016/j.biortech.2019.122492] |
5. Lele Jin, Wenzhi Li, Qiying Liu, Longlong Ma, Song Li, Yang Liu, Baikai Zhang, Qi Zhang. (2019) Catalytic conversion of cellulose to C5/C6 alkanes over Ir-VOx/SO2 combined with HZSM-5 in n-dodecane/water system. FUEL PROCESSING TECHNOLOGY, 196 (106161). [PMID:] [10.1016/j.fuproc.2019.106161] |
6. Yuan-Yuan Cui, Huan Yao, Cheng-Xiong Yang, Xiu-Ping Yan. (2019) In situ fabrication of microporous organic network coated capillary column for high resolution gas chromatographic separation of hydrocarbons. ELECTROPHORESIS, 40 (16-17): (2186-2192). [PMID:30942493] [10.1002/elps.201800540] |
7. Lin Fan, Xiu-Ping Yan. (2012) Evaluation of isostructural metal–organic frameworks coated capillary columns for the gas chromatographic separation of alkane isomers. TALANTA, 99 (944). [PMID:22967647] [10.1016/j.talanta.2012.07.063] |
8. Xue Xiong,Meiling Qi. (2018-08-14) Hexagonal boron nitride stationary phase for gas chromatography.. Journal of chromatography. A, 1567 (191-197). [PMID:30100014] |
9. Qian Yuan,Meiling Qi. (2020-04-19) Triptycene-based dicationic guanidinium ionic liquid: A novel stationary phase of high selectivity towards a wide range of positional and structural isomers.. Journal of chromatography. A, 1621 (461084-461084). [PMID:32303345] |