Click Here for 5% Off Your First Aladdin Purchase!

Cell cycle assay kit plus (upgraded version of cell cycle detection kit)

Item Number
C598381
Grouped product items
SKUSizeAvailabilityPrice Qty
C598381-50T
50T
Available within 8-12 weeks(?)
Production requires sourcing of materials. We appreciate your patience and understanding.
$360.90

Basic Description

Storage TempProtected from light,Store at -20°C
Shipped InIce chest + Ice pads
Product Description

Product introduction:

Product introduction:Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) has certain applicability for live cells and fixed cell cycle detection. For different types of cells, whether it is applicable or not needs to be determined after testing. Cell Cycle Assay Kit Plus ( Cell Cycle Assay Kit Plus ) uses RedNucleus I staining to detect cell cycle. RedNucleus I is a far-infrared nucleic acid dye with cell membrane permeability, which can quickly enter living cells, specifically bind to DNA, and perform cell cycle detection on living cells without RNase digestion. Compared with the traditional PI staining method, the cells do not need to be broken or fixed, and the operation is simpler. RedNucleus I is a fluorescent dye of double-stranded DNA, and the fluorescence intensity after binding to double-stranded DNA is proportional to the content of double-stranded DNA. The intracellular DNA content can be measured by flow cytometry, and then the cell cycle analysis can be carried out according to the distribution of DNA content. After RedNucleus I staining, assuming that the fluorescence intensity of G0 / G1 phase cells is 1, the theoretical value of the fluorescence intensity of G2 / M phase cells containing two copies of genomic DNA is 2, and the fluorescence intensity of S phase cells undergoing DNA replication is between 1-2. In addition, RedNucleus I is compatible with dyes such as Horizon BV / BUV, FITC and R-PE, and can be periodically detected after sample staining.The kit is usually used to detect the cell cycle of cultured adherent or suspended cells. If it is used for cell cycle detection of tissues, the tissues must be digested into a single cell state.

Matters needing attention:

1. please centrifuge the product to the bottom of the tube immediately before use, and then conduct subsequent experiments. 2. this product is applicable to the detection of living cells and fixed cell cycle with certain limitations. Whether it is applicable to different types of cells needs to be determined after testing. If fixation is needed, it is recommended to use ice bath pre cooling 75-80% ethanol -20 ℃ to fix cells overnight. 3. fluorescent dyes have quenching problems. Please try to avoid light during storage and use to slow down fluorescence quenching. 4. for your safety and health, please wear experimental clothes and disposable gloves.

Instruction: 

Experimental materials ( self-provided ):

①cell lines or other cell samples ( self-prepared ) ;

②This kit ; 

③ trypsin ( self-prepared ) ;

④ Cell culture medium containing FBS ( self-prepared ) ; 

Experimental procedure: 

1.Preparation of cell samples : ( 1 ) ( This step is for adherent cells, if suspended cells, can be carried out directly step ( 2 ) ) Digest cells with trypsin, add cell culture medium, gently blow away cells, collected into the centrifuge tube. Note : The number of cells on the machine needs to reach 50,000 and above, so the initial number of cells collected needs to be sufficient. 

( 2 ) Centrifuged about 1000 g for 3-5 min to precipitate cells. Carefully remove the supernatant, add about 1 mL of ice bath pre-cooled 1 × staining buffer ( 10 × staining buffer diluted with diH2O at 1 : 10 ), re-suspend the cells. Repeat once. 

( 3 ) Centrifuged about 1000 g for 3-5 min to precipitate cells. After the supernatant was discarded, 1 mL of culture medium was added to re-suspend the cells ( for fixed cells, 1 × PBS can also be used to re-suspend ). Gently flick the bottom of the centrifuge tube to properly disperse the cells to avoid cell aggregation. 

2.Staining : 4 μL of RedNucleus I staining solution was added to each tube of cell samples, slowly and fully mixed, and incubated at room temperature in dark for 20 min ( or incubated at 37 ° C in dark for 5-10 min ). The optimal incubation time of different cells is different, and the staining time can be adjusted and optimized according to the actual staining effect to obtain a more ideal staining effect. 

3.Flow cytometry detection and analysis : Excited at 638 nm by flow cytometry, it is recommended to detect in RL3 or FL4 channels, or use RL1 and RL2 channels. Cell DNA content analysis and light scattering analysis were performed using appropriate analysis software.

Scope of application:

Cell cycle detection

Certificates

Certificate of Analysis(COA)

Enter Lot Number to search for COA:

To view the certificate results,please click on a Lot number.For Lot numbers from past orders,please use our order status section

1 results found

Lot NumberCertificate TypeDateItem
H2422567Certificate of AnalysisApr 08, 2024 C598381

Chemical and Physical Properties

SensitivityHeat sensitive;Light sensitive

Related Documents

Solution Calculators