Hemoglobin Assay Kit - sufficient for 250colorimetrictests, high purity

Item Number
H486474
Grouped product items
SKUSizeAvailabilityPrice Qty
H486474-100T
100T
Available within 8-12 weeks(?)
Production requires sourcing of materials. We appreciate your patience and understanding.
$219.90
H486474-1kit
1kit
Available within 8-12 weeks(?)
Production requires sourcing of materials. We appreciate your patience and understanding.
$905.90

Basic Description

Legal InformationTriton is a trademark of The Dow Chemical Company or an affiliated company of Dow
Storage TempProtected from light,Store at -20°C
Shipped InIce chest + Ice pads
Product Description

Hemoglobin (Hb or HGB) is a protein responsible for carrying oxygen in higher organisms and is the protein that makes blood appear red. Hemoglobin is composed of four chains, two alpha chains and two beta chains, each with a cyclic heme containing one iron atom. Hb is easily bound to oxygen in areas with high oxygen content; In areas with low oxygen content, it is easy to separate from oxygen. The characteristic of hemoglobin enables red blood cells to transport oxygen.
The detection principle of BIOISCO Hemoglobin Colorimetric Assay Kit is that heme in hemoglobin has a peroxidase like effect, which can catalyze the chromogenic substrate under the action of oxidants. Under acidic conditions, the product appears red with an absorption peak. The darker the red color of the product, the higher the Hb content, otherwise it is lower. The absorbance at the site is measured by an enzyme-linked immunosorbent assay (ELISA) reader, and the hemoglobin content level in the serum can be calculated through colorimetric analysis. This kit is mainly used to detect hemolytic serum samples, and can also be used to detect hemoglobin content in cell or tissue lysates or homogenates. This kit is only used in the field of scientific research and should not be used for clinical diagnosis or other purposes.
Storage conditions:
Save as required, valid for six months.
Self provided materials:
Physiological saline, 96 well plate, water bath or constant temperature box, enzyme-linked immunosorbent assay (ELISA) reader

Components:

ComponentsH486474-100TStorage
Reagent (A): Hb Assay buffer5ml-20℃ protect from light
Reagent (B): chromogenic substrate2x100μl-20℃
Reagent (C): Acid Assay buffer17mlRT
Reagent (D): Hb(1mg/ml)50μl-20℃ protect from light
Reagent  (E): ddH2O1mlRT

Matters needing attention:
1. Hb (1mg/ml) and standard working solution (13.2 μ g/ml) should be stored at -20 ℃, and repeated freezing and thawing should be avoided.
2. If there is no enzyme-linked immunosorbent assay (ELISA) reader, a regular spectrophotometer can also be used for measurement, but consideration should be given to using the minimum detection volume of the colorimetric cup as much as possible
Use a small-sized colorimetric cup.
3. After preparing one color developing working solution, it should be used up as soon as possible, so please prepare more samples for testing.
Operation steps (for reference only):
1. Preparation of testing working fluid:
① Preparation of standard working solution: Take Hb (1mg/ml) and restore it to room temperature. Accurately take it and add ddH2O to obtain the standard working solution (13.2 μ g/ml).
② Preparation of colorimetric working solution: Take Hb Assay buffer and restore it to room temperature. Dissolve 20 μ l of colorimetric substrate in 2ml Hb Assay buffer,
It is the color developing working fluid. The prepared color developing working solution should be stored at -20 ℃ and generally used up within one day.
2. Prepare samples:
① Hemolytic specimen serum: Hemolytic serum is prepared according to conventional methods and frozen at -20 ℃. Dilute with physiological saline during use.
② Cell or tissue samples: Take appropriate cell or tissue lysate, homogenize if necessary, centrifuge at low speed to obtain supernatant, and freeze at 20 ℃.
3 Hb sample addition: Set the blank hole, standard hole, and measuring hole of the 96 well plate according to the table below. The solution should be added in sequence, and attention should be paid to avoiding the generation of bubbles. If the hemoglobin content in the sample is too high, the sample dosage can be reduced or adjusted appropriately
Dilute before conducting the measurement. It is best to set parallel holes for sample testing, especially for standard samples, which should have three replicates.

Added items(μl)Blank holeStandard holeMeasurement hole
ddH 2O8
Standard working fluid8
Sample to be tested8
Color developing working fluid404040
Gently mix well and incubate accurately at 37 ℃ for 10 minutes
Acid Assay buffer160160160

4. Enzyme linked immunosorbent assay (ELISA) detection: The absorbance at 530nm is A530. If it cannot be detected, the absorbance can also be detected, usually within a few hours.
Calculation result:
Serum hemoglobin (mg/L)=absorbance of the test sample/absorbance of the standard sample × 13.2 × 100 (mg/L)

Certificates

C of A & Other Certificates(BSE/TSE, COO)

Chemical and Physical Properties

Sensitivitylight sensitive

Related Documents

References

1. Malthe Hvas,Egil Karlsbakk,Stig Mæhle,Daniel William Wright,Frode Oppedal.  (2017-12-09)  The gill parasite Paramoeba perurans compromises aerobic scope, swimming capacity and ion balance in Atlantic salmon..  Conservation physiology,  ((1)): (cox066-cox066).  [PMID:29218225]
2. Malthe Hvas,Ole Folkedal,Albert Imsland,Frode Oppedal.  (2018-08-18)  Metabolic rates, swimming capabilities, thermal niche and stress response of the lumpfish, Cyclopterus lumpus..  Biology open,  ((9)):   [PMID:30115616]
3. Daniel F Gomez Isaza,Rebecca L Cramp,Richard Smullen,Brett D Glencross,Craig E Franklin.  (2019-01-20)  Coping with climatic extremes: Dietary fat content decreased the thermal resilience of barramundi (Lates calcarifer)..  Comparative biochemistry and physiology. Part A, Molecular & integrative physiology,  230  (64-70).  [PMID:30659952]
4. Garrett W Hill,Trevor L Gillum,Ben J Lee,Phebe A Romano,Zach J Schall,Ally M Hamilton,Matthew R Kuennen.  (2019-09-11)  Prolonged treadmill running in normobaric hypoxia causes gastrointestinal barrier permeability and elevates circulating levels of pro- and anti-inflammatory cytokines..  Applied physiology, nutrition, and metabolism = Physiologie appliquee, nutrition et metabolisme,  45  ((4)): (376-386).  [PMID:31505122]
5. Daniel F Gomez Isaza,Rebecca L Cramp,Craig E Franklin.  (2020-01-29)  Simultaneous exposure to nitrate and low pH reduces the blood oxygen-carrying capacity and functional performance of a freshwater fish..  Conservation physiology,  ((1)): (coz092-coz092).  [PMID:31988749]
6. Cheng Chen,Mengjia Lu,Shuo Lin,Wei Qin.  (2020-02-23)  The nuclear gene rpl18 regulates erythroid maturation via JAK2-STAT3 signaling in zebrafish model of Diamond-Blackfan anemia..  Cell death & disease,  11  ((2)): (135-135).  [PMID:32075953]
7. Jung Hwa Park,Min Jae Kim,Woo Jean Kim,Ki-Dong Kwon,Ki-Tae Ha,Byung Tae Choi,Seo-Yeon Lee,Hwa Kyoung Shin.  (2020-03-17)  Isolinderalactone suppresses human glioblastoma growth and angiogenic activity in 3D microfluidic chip and in vivo mouse models..  Cancer letters,  478  (71-81).  [PMID:32173479]
8. Malthe Hvas,Lars Helge Stien,Frode Oppedal.  (2021-02-02)  The effect of fasting period on swimming performance, blood parameters and stress recovery in Atlantic salmon post smolts..  Comparative biochemistry and physiology. Part A, Molecular & integrative physiology,  255  (110913-110913).  [PMID:33524618]
9. Daniel F Gomez Isaza,Rebecca L Cramp,Craig E Franklin.  (2021-02-03)  Exposure to Nitrate Increases Susceptibility to Hypoxia in Fish..  Physiological and biochemical zoology : PBZ,  94  ((2)): (124-142).  [PMID:33529124]
10. Rachel P L van Swelm,Jack F M Wetzels,Vivienne G M Verweij,Coby M M Laarakkers,Jeanne C L M Pertijs,Jenny van der Wijst,Frank Thévenod,Rosalinde Masereeuw,Dorine W Swinkels.  (2016-01-31)  Renal Handling of Circulating and Renal-Synthesized Hepcidin and Its Protective Effects against Hemoglobin-Mediated Kidney Injury..  Journal of the American Society of Nephrology : JASN,  27  ((9)): (2720-2732).  [PMID:26825531]
11. M J Faulkner,N R St-Pierre,W P Weiss.  (2017-05-01)  Effect of source of trace minerals in either forage- or by-product-based diets fed to dairy cows: 2. Apparent absorption and retention of minerals..  Journal of dairy science,  100  ((7)): (5368-5377).  [PMID:28456401]
12. Baris R Mutlu,Kyle C Smith,Jon F Edd,Priyanka Nadar,Mcolisi Dlamini,Ravi Kapur,Mehmet Toner.  (2017-09-01)  Non-equilibrium Inertial Separation Array for High-throughput, Large-volume Blood Fractionation..  Scientific reports,  ((1)): (9915-9915).  [PMID:28855584]
13. Essie M Rodgers,Craig E Franklin.  (2017-10-06)  Physiological mechanisms constraining ectotherm fright-dive performance at elevated temperatures..  The Journal of experimental biology,  220  ((Pt 19)): (3556-3564).  [PMID:28978640]
14. Huashu Ma,Zongxu Qiao.  (2018-06-16)  Analysis of the efficacy of resveratrol treatment in patients with scarred uterus..  Experimental and therapeutic medicine,  15  ((6)): (5410-5414).  [PMID:29904420]
15. Viviana Lo Martire,Sara Alvente,Stefano Bastianini,Chiara Berteotti,Alice Valli,Mauro Manconi,Giovanna Zoccoli,Alessandro Silvani.  (2019-01-09)  Sleep and Tibialis Anterior Muscle Activity in Mice With Mild Hypoxia and Iron Deficiency: Implications for the Restless Legs Syndrome..  Frontiers in physiology,  (1818-1818).  [PMID:30618828]
16. Heechun Kwak,Sumin Lee,Seunghyun Jo,Young Eun Kwon,Hyunju Kang,Gahee Choi,Myung Eun Jung,Mi-Jeong Kwak,Seonghoon Kim,Byung-Ha Oh,Dong-Sik Kim,Sung Ho Hwang.  (2020-12-15)  MG1113, a specific anti-tissue factor pathway inhibitor antibody, rebalances the coagulation system and promotes hemostasis in hemophilia..  Research and practice in thrombosis and haemostasis,  ((8)): (1301-1312).  [PMID:33313469]

Solution Calculators