Human Genomic DNA Quantification Kit

Item Number
H665940
Grouped product items
SKUSizeAvailabilityPrice Qty
H665940-1ml
1ml
Available within 8-12 weeks(?)
Production requires sourcing of materials. We appreciate your patience and understanding.
$499.90
H665940-5ml
5ml
Available within 8-12 weeks(?)
Production requires sourcing of materials. We appreciate your patience and understanding.
$1,999.90

Basic Description

Storage TempStore at -20°C,Avoid repeated freezing and thawing
Shipped InIce chest + Ice pads
Product Description

Product content

H665940Component1 mL5 mLStorage
H665940A2×GoldStar TaqMan Mixture1 mL5×1 mL-20°C. Avoid freeze/thaw cycle.
H665940BPrimer Mix 1300 µL5×300 µL-20°C. Avoid freeze/thaw cycle.
H665940CHuman DNA Standard 1 (100 ng/µL)100 µL5×100 µL-20°C. Avoid freeze/thaw cycle.
H665940D50×High rox40 µL200 µL-20°C. Avoid freeze/thaw cycle.

Product Introduction

This product is a real-time fluorescence quantitative PCR (qPCR) using the probe method, which realizes the accurate detection of the concentration and quality of DNA extracted from various samples (paraffin samples, flow-sorted cells, serum or plasma samples and a small number of clinical samples, etc.). The product provides a full set of reagents required in the qPCR process, including reaction mix, primer mixtures, and standards. Simply add the extracted DNA and start the experiment, which is easy and convenient to operate and saves time and labor. The reaction mixture uses highly efficient and fast hot-start GoldStar Taq DNA Polymerase, which has high amplification sensitivity, good specificity and shortens the program reaction time.

ROX dye is used to correct the fluorescence signal error generated between wells of a quantitative PCR instrument, and is generally used in Real Time PCR amplifiers from ABI, Stratagene, and other companies. The excitation optics vary from instrument to instrument, so the concentration of ROX dye must be matched to the corresponding fluorescence quantitative PCR instrument.

Instruments that do not require ROX calibration: Roche LightCycler 480, Roche LightCyler 96, Bio-rad iCyler iQ, iQ5, CFX96, etc.

Instruments requiring Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio®3 System, QuantStudio®5 System, QuantStudio®6 Flex System, QuantStudio®7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, and others.

Instruments requiring High ROX calibration: ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.

Note: High Rox and Low Rox are formulated as described in Method of Use 3.

Applicable scope

This product is suitable for quantitative detection of human genomic DNA sample concentration in scientific research, clinical, forensic medicine and paternity testing.

Usage

1. Amplification template preparation

The samples to be detected were diluted with TE (10 mM Tris-Cl, pH 8.0, 1 mM EDTA), and the concentration after dilution was as close as possible to the range of 0.05-10 ng/μl. The samples were placed on ice at 4°C and set aside.

2. Standard dilution: according to the following table, firstly dilute Human DNA Standard 1 (100ng/ul) with TE to make 5 different concentrations of standard according to the table below. 10ng/μl of DNA Standard 1 (Std.1) can be stored stably at -20℃ for 1 month; Std2-5 can only be used on the same day, and should be placed at 4℃ or on ice when not in use for the time being after preparation. When not used temporarily after preparation, it should be kept at 4℃ or on ice.

Standard sample

Corresponding concentration(ng/μl)

Minimum Dilution Volume (Unit: μ L)

Std.1

10

10 [100 ng/μl DNA Standard 1]+ 90 TE

Std.2

2.5

20 [Std. 1] +60 TE

Std.3

0.625

20 [Std. 2] +60 TE

Std.4

0.15625

20 [Std. 3] +60 TE

Std.5

0.0390625

20 [Std. 4] +60 TE

3. qPCR reaction system preparation

The cryopreserved reagents to be used were completely melted and mixed by inversion several times before preparation, and then briefly centrifuged and prepared for use. 20 μl of the base reaction system was as follows.

The base reaction system for 20 μl was as follows:

Reagent20 μl Reaction system
2×GoldStar TaqMan Mixture10 μl
Primer Mix3 μl
Template4 μl
ddH₂O3 μl

Note: High Rox model: add 1 μl of 50×High Rox per 50 μl of reaction system; Low Rox model: add 1 μl of 50×High Rox per 500 μl of reaction system.

A sufficient amount of reaction system mixture was prepared according to the need, and after the reaction system was prepared and mixed thoroughly, it was added to the reaction wells in a volume of 16 μl per well. Then add the prepared standards and diluted samples into the corresponding reaction wells, the amount added is 4μl/well. TE was added to the blank control tube, and the same amount was added at 4 μl/well.

It is recommended to use 20 μl of reaction, if you need to carry out a smaller system reaction, the system components can be reduced in equal proportion.

4. qPCR reaction program

The PCR mix in this kit contains a FAM fluorescent probe for the target gene and a VIC fluorescent probe with internal reference to Internal PCR Control (IPC). qPCR program with dual fluorescence of hydrolyzed probes needs to be selected for the assay. Please set up the program according to the instructions of your instrument.

PCR reaction temperature conditions were as follows:


Data analysis
1. Standard curve production

The standard curve was plotted with reference to the Excel sheet for data processing. The correlation coefficient R2 of the standard curve should be not less than 0.98, and the slope should be located between -3.1 and -3.6 when the Ct value is used as the longitudinal coordinate. If the parameters of the standard curve are unreasonable, it is recommended to repeat the experiment.

DNA Standard NameDNA Standard Concentration(ng/μl)
DNA Standard 110
DNA Standard 22.5
DNA Standard 30.625
DNA Standard 40.15625
DNA Standard 50.0390625

2. Analysis of results and calculation of concentrations

The Ct difference between experimental replicate wells for FAM signaling of the target gene should be no more than 0.3, otherwise invalid data need to be deleted or the experiment needs to be repeated, do not use Ct outside the valid Ct range of the standard curve to calculate the concentration of the sample.

Specific calculations of sample concentrations were made with reference to the data processing Excel sheet.

If the FAM signal is abnormal, the VIC signal of the internal reference Internal PCR Control (IPC) should be analyzed to confirm whether the PCR reaction process is abnormal. If the Ct value of the VIC signal of the sample wells is significantly larger than that of the standard or blank control wells, it means that the sample has inhibited the PCR reaction.

matters needing attention

1. Before testing, these instructions should be read in detail. It should be operated by personnel with professional experience or qualified by training.

2. For use, please mix gently by turning up and down, avoid foaming as much as possible, and use it after centrifugation for a short period of time.

3. Avoid repeated freezing and thawing of the product, repeated freezing and thawing may degrade the performance of the product.

4. When preparing the reaction solution, please use new or non-contaminated tips and centrifuge tubes to try to prevent contamination.

Certificates

Certificate of Analysis(COA)

Enter Lot Number to search for COA:

Solution Calculators