IgG/RF Adsorbent

  • ≥95%
  • ≥2mg/ml
    Application:
  • CLIA
  • EIA
  • LF
Features and benefits
    Item Number
    Ab175946
    Grouped product items
    SKUSizeAvailabilityPrice Qty
    Ab175946-5mg
    5mg
    Available within 8-12 weeks(?)
    Production requires sourcing of materials. We appreciate your patience and understanding.
    $119.90
    Ab175946-50mg
    50mg
    Available within 8-12 weeks(?)
    Production requires sourcing of materials. We appreciate your patience and understanding.
    $639.90
    View related series
    Adsorbent

    Basic Description

    Product NameIgG/RF Adsorbent
    Specifications & Purity≥95%, ≥2mg/ml
    ImmunogenHuman IgG Fc
    Product Description

    Product Description:
    Active blocker, recommended for IgM detection products.
    IgM antibody detection is an effective diagnostic method to determine the initial or early infection of pathogens. Rheumatoid factor (RF) and specific IgG antibodies in serum samples may affect the specificity and sensitivity of detection reagents, resulting in erroneous results. Using IgG/RF adsorbent to pretreat samples to remove the above-mentioned substances that may interfere is the simplest and fastest way to improve detection specificity, sensitivity and stability.
    Goat anti-human IgG (Fc) antibody (0.01M PBS, pH7.4), purified by antigen affinity chromatography, with a purity ≥ 95%, filtered through 0.2 μm, without adding preservatives.
    Filtration: 0.2um
    Notes:
    Long-term storage should be ≤-20°C. The product can be stored at 2°C-8°C for a short period of time without opening, and the storage time should not exceed 7 days. Because this product does not add any preservatives, if it is opened and used, it is not recommended to store it at 2-8°C. For long-term storage at ℃, it should be subpackaged and stored at ≤-20℃.
    Technical background:
    Specific IgM detection is a serological diagnostic method for judging the initial or early infection of pathogens. Rheumatoid factor (RF) and specific IgG antibodies in serum samples may affect the specificity and sensitivity of detection reagents, resulting in erroneous results. It is the simplest and fastest way to improve the specificity, sensitivity and stability of detection by using IgG/RF adsorbent, a special blocking agent for IgM detection, to pretreat the sample to remove the above-mentioned substances that may interfere.
    Action principle:
    After the adsorbent is in contact with the sample, the IgG antibody in the serum reacts with the adsorbent to form an IgG complex, which prevents it from competing with the IgM to be tested for antigen binding, and improves the detection sensitivity. At the same time, the rheumatoid factor (RF) that may exist in the sample will be eliminated. The IgG complex is adsorbed to remove its interference to the detection process.
    Method of application:
    1. Immunochromatographic products
    The adsorbent can be added to the sample processing pad at a certain concentration, and the concentration used is determined through a gradient test according to the amount of sample used.
    2. ELISA products
    2.1. The sample can be pretreated by adding the adsorbent to the sample diluent.
    2.2. Determine the content of the adsorbent in the sample diluent according to the sample usage and dilution of the corresponding product, and the most suitable concentration should be determined through a gradient test.
    2.3. The pretreatment time is between 5 and 30 minutes and should be determined experimentally.
    2.4. The pretreated sample may appear turbid due to IgG complexes. It can be centrifuged at low speed for 2-3 minutes to remove the precipitate and take the supernatant for detection. If it is verified that the turbid sample has no effect on the experimental results, it can be directly tested.
    2.5. The effect of adding adsorbents on the reaction system in the sample dilution should be fully considered to ensure that the active ingredients in the sample dilution are not affected by the adsorbent.
    3. Other IgM detection products The use method and concentration of the adsorbent should be determined according to the corresponding technical route and detection method. An inappropriate concentration of the adsorbent may cause precipitation, and the most suitable concentration should be selected through experiments

    Product Properties

    Purification MethodAntigen affinity chromatography
    FormLiquid
    Concentration≥2mg/ml
    Storage TempStore at -20°C
    Shipped InIce chest + Ice pads

    Images

    IgG/RF 吸附剂 (Ab175946) - SDS-PAGE
    3 μg/lane of IgG/RF adsorbent (Ab175946) was resolved with SDS-PAGE under reducing (R) and non-reducing (N) conditions and visualized by Coomassie® Blue staining. Showing the band at 26.7 kDa (Light Chain) & 51.8 kDa (Heavy Chain), under reducing conditions; 158.2 kDa, under non-reducing conditions. The purity of the IgG/RF adsorbent is greater than 95%.

    Certificates

    Certificate of Analysis(COA)

    Enter Lot Number to search for COA:

    Find and download the COA for your product by matching the lot number on the packaging.

    2 results found

    Lot NumberCertificate TypeDateItem
    ZJ24F0607006Certificate of AnalysisJun 19, 2024 Ab175946
    ZJ24F0607005Certificate of AnalysisJun 19, 2024 Ab175946

    Related Documents

    Solution Calculators