Poly(ethylene-alt-maleic anhydride) - average Mw 100,000-500,000, powder, high purity , CAS No.9006-26-2

  • average Mw 100,000-500,000, powder
Item Number
P434514
Grouped product items
SKUSizeAvailabilityPrice Qty
P434514-5g
5g
Available within 4-8 weeks(?)
Items will be manufactured post-order and can take 4-8 weeks. Thank you for your patience!
$59.90
P434514-25g
25g
Available within 8-12 weeks(?)
Production requires sourcing of materials. We appreciate your patience and understanding.
$159.90

Basic Description

Synonymsethene;furan-2,5-dione | 9006-26-2 | ethylene/maleic anhydride | SCHEMBL55173 | DTXSID60945009 | YYXLGGIKSIZHSF-UHFFFAOYSA-N | Furan-2,5-dione--ethene (1/1) | 223537-61-9
Specifications & Purityaverage Mw 100,000-500,000, powder
Product Description

Forms a gel in water. Films from aqueous or organic solutions have high tensile and cohesive strength.Alternating copolymer of ethylene-maleic anhydride.

Application

Viscosity modifier for solution, suspension or emulsion. Dispersing aid for insoluble solids.

Names and Identifiers

IUPAC Name ethene;furan-2,5-dione
INCHI InChI=1S/C4H2O3.C2H4/c5-3-1-2-4(6)7-3;1-2/h1-2H;1-2H2
InChi Key YYXLGGIKSIZHSF-UHFFFAOYSA-N
Canonical SMILES C=C.C1=CC(=O)OC1=O
Isomeric SMILES C=C.C1=CC(=O)OC1=O
PubChem CID 62700

Certificates

Certificate of Analysis(COA)

Enter Lot Number to search for COA:

To view the certificate results,please click on a Lot number.For Lot numbers from past orders,please use our order status section

6 results found

Lot NumberCertificate TypeDateItem
L2313505Certificate of AnalysisNov 15, 2023 P434514
L2313506Certificate of AnalysisNov 15, 2023 P434514
L2313507Certificate of AnalysisNov 15, 2023 P434514
L2313512Certificate of AnalysisNov 15, 2023 P434514
E2325831Certificate of AnalysisMay 17, 2023 P434514
G2306139Certificate of AnalysisMay 17, 2023 P434514

Chemical and Physical Properties

SensitivityMoisture sensitive

Safety and Hazards(GHS)

Pictogram(s) GHS07
Signal Warning
Hazard Statements

H315:Causes skin irritation

H319:Causes serious eye irritation

Precautionary Statements

P305+P351+P338:IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do - continue rinsing.

P280:Wear protective gloves/protective clothing/eye protection/face protection.

P302+P352:IF ON SKIN: wash with plenty of water.

P321:Specific treatment (see ... on this label).

P264:Wash hands [and …] thoroughly after handling.

P362+P364:Take off contaminated clothing and wash it before reuse.

P264+P265:Wash hands [and …] thoroughly after handling. Do not touch eyes.

P337+P317:If eye irritation persists: Get medical help.

P332+P317:If skin irritation occurs: Get medical help.

Related Documents

References

1. H Neumann,Y Levin.  (1985-06-01)  Twentyfold increase in alkaline phosphatase activity by sequential reversible activation of the enzyme followed by coupling with a copolymer of ethylene and maleic anhydride..  Applied biochemistry and biotechnology,  11  ((3)): (177-189).  [PMID:4051477]
2. E Baloğlu,M Ozyazici,S Y Hizarcioğlu,H A Karavana.  (2003-05-06)  An in vitro investigation for vaginal bioadhesive formulations: bioadhesive properties and swelling states of polymer mixtures..  Farmaco (Societa chimica italiana : 1989),  58  ((5)): (391-396).  [PMID:12729833]
3. Tilo Pompe,Lars Renner,Milauscha Grimmer,Nicole Herold,Carsten Werner.  (2005-09-01)  Functional films of maleic anhydride copolymers under physiological conditions..  Macromolecular bioscience,  ((9)): (890-895).  [PMID:16134087]
4. J K Song,H J Choi,I Chin.  (2007-04-19)  Preparation and properties of electrophoretic microcapsules for electronic paper..  Journal of microencapsulation,  24  ((1)): (11-19).  [PMID:17438939]
5. Sijing Xiong,Saji George,Zhaoxia Ji,Sijie Lin,Haiyang Yu,Robert Damoiseaux,Bryan France,Kee Woei Ng,Say Chye Joachim Loo.  (2012-08-14)  Size of TiO(2) nanoparticles influences their phototoxicity: an in vitro investigation..  Archives of toxicology,  87  ((1)): (99-109).  [PMID:22885792]
6. C Minard-Basquin,C Chaix,C Pichot.  (2001-09-21)  The use of (oligonucleotide-maleic anhydride copolymer) conjugates in nucleic acid diagnostic assays: effect of the number of oligonucleotides per polymer on test sensitivity improvement..  Nucleosides, nucleotides & nucleic acids,  20  ((4-7)): (895-899).  [PMID:11563140]

Solution Calculators