Sodium Bis(trifluoromethanesulfonyl)imide - >98.0%(T), high purity , CAS No.91742-21-1

  • ≥98%(T)
Item Number
S161091
Grouped product items
SKUSizeAvailabilityPrice Qty
S161091-250mg
250mg
In stock
$29.90
S161091-1g
1g
In stock
$69.90
S161091-5g
5g
In stock
$199.90
S161091-25g
25g
In stock
$399.90
S161091-100g
100g
In stock
$699.90

Basic Description

SynonymsCS-0154338 | SY068093 | sodium bis(trifluoromethanesulfonyl)amide | sodiumbis(trifluoromethanesulfonyl)imide | SCHEMBL300203 | T73067 | SB66341 | Bis(trifluoromethanesulfonyl)imide Sodium Salt | NaTFSI | Sodium Triflimide | Sodium trifluoromethanesulfonim
Specifications & Purity≥98%(T)
Storage TempArgon charged
Shipped InNormal
Note250mg卖完停产,不再备货
Product Description

Uses: . Electrolyte for batteries and fuel cells . Ionic liquids . Lewis acids

Names and Identifiers

Pubchem Sid488197137
Pubchem Sid Urlhttps://pubchem.ncbi.nlm.nih.gov/substance/488197137
IUPAC Name sodium;bis(trifluoromethylsulfonyl)azanide
INCHI InChI=1S/C2F6NO4S2.Na/c3-1(4,5)14(10,11)9-15(12,13)2(6,7)8;/q-1;+1
InChi Key YLKTWKVVQDCJFL-UHFFFAOYSA-N
Canonical SMILES C(F)(F)(F)S(=O)(=O)[N-]S(=O)(=O)C(F)(F)F.[Na+]
Isomeric SMILES C(F)(F)(F)S(=O)(=O)[N-]S(=O)(=O)C(F)(F)F.[Na+]
WGK Germany 3
PubChem CID 11077530
UN Number 1759
Packing Group II
Molecular Weight 303.13
Reaxy-Rn 4775654

Certificates

Certificate of Analysis(COA)

Enter Lot Number to search for COA:

Find and download the COA for your product by matching the lot number on the packaging.

47 results found

Lot NumberCertificate TypeDateItem
J2422780Certificate of AnalysisOct 12, 2024 S161091
J2422767Certificate of AnalysisOct 12, 2024 S161091
J2422768Certificate of AnalysisOct 12, 2024 S161091
G2424153Certificate of AnalysisJul 08, 2024 S161091
G2424154Certificate of AnalysisJul 08, 2024 S161091
G2424155Certificate of AnalysisJul 08, 2024 S161091
E2409440Certificate of AnalysisApr 10, 2024 S161091
E2409450Certificate of AnalysisApr 10, 2024 S161091
E2409458Certificate of AnalysisApr 10, 2024 S161091
D2415286Certificate of AnalysisMar 12, 2024 S161091
D2415296Certificate of AnalysisMar 12, 2024 S161091
B24231097Certificate of AnalysisJan 20, 2024 S161091
B24231098Certificate of AnalysisJan 20, 2024 S161091
B24231096Certificate of AnalysisJan 20, 2024 S161091
B24231095Certificate of AnalysisJan 20, 2024 S161091
B24231094Certificate of AnalysisJan 20, 2024 S161091
B24231093Certificate of AnalysisJan 20, 2024 S161091
J2323653Certificate of AnalysisOct 09, 2023 S161091
J2323652Certificate of AnalysisOct 09, 2023 S161091
J2323651Certificate of AnalysisOct 09, 2023 S161091
A2408191Certificate of AnalysisOct 09, 2023 S161091
I2301740Certificate of AnalysisAug 17, 2023 S161091
I2301723Certificate of AnalysisAug 17, 2023 S161091
I2301718Certificate of AnalysisAug 17, 2023 S161091
I2301715Certificate of AnalysisAug 17, 2023 S161091
I2301485Certificate of AnalysisAug 17, 2023 S161091
I1906036Certificate of AnalysisJun 09, 2023 S161091
G23131259Certificate of AnalysisJun 08, 2023 S161091
G23131342Certificate of AnalysisJun 08, 2023 S161091
G23131300Certificate of AnalysisJun 08, 2023 S161091
G23131280Certificate of AnalysisJun 08, 2023 S161091
G23121355Certificate of AnalysisJun 08, 2023 S161091
E23301300Certificate of AnalysisJun 06, 2023 S161091
E23301332Certificate of AnalysisJun 06, 2023 S161091
E23301287Certificate of AnalysisJun 06, 2023 S161091
E23301295Certificate of AnalysisJun 06, 2023 S161091
E23301293Certificate of AnalysisJun 06, 2023 S161091
K2201692Certificate of AnalysisSep 14, 2022 S161091
K2201721Certificate of AnalysisSep 14, 2022 S161091
K2201727Certificate of AnalysisSep 14, 2022 S161091
K2201728Certificate of AnalysisSep 14, 2022 S161091
K2201764Certificate of AnalysisSep 14, 2022 S161091
C23161449Certificate of AnalysisSep 14, 2022 S161091
B2318386Certificate of AnalysisSep 14, 2022 S161091
G2219207Certificate of AnalysisJul 28, 2022 S161091
C2218006Certificate of AnalysisApr 06, 2022 S161091
I2206053Certificate of AnalysisNov 27, 2021 S161091

Show more⌵

Chemical and Physical Properties

SolubilityDissolved in water
SensitivityMoisture sensitive
Melt Point(°C)257.1-258.4°C

Safety and Hazards(GHS)

Pictogram(s) GHS05
Signal Danger
Hazard Statements

H314:Causes severe skin burns and eye damage

Precautionary Statements

P280:Wear protective gloves/protective clothing/eye protection/face protection.

P321:Specific treatment (see ... on this label).

P405:Store locked up.

P501:Dispose of contents/container to ...

P264:Wash hands [and …] thoroughly after handling.

P260:Do not breathe dust/fume/gas/mist/vapors/spray.

P301+P330+P331:IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.

P304+P340:IF INHALED: Remove person to fresh air and keep comfortable for breathing.

P363:Wash contaminated clothing before reuse.

P305+P354+P338:IF IN EYES: Immediately rinse with water for several minutes. Remove contact lenses if present and easy to do. Continue rinsing.

P302+P361+P354:IF ON SKIN: Take off Immediately all contaminated clothing. Immediately rinse with water for several minutes.

P316:Get emergency medical help immediately.

WGK Germany 3
Reaxy-Rn 4775654
Class 8

Related Documents

Citations of This Product

1. Wei Zhao, Yiwei Zheng, Meng Jiang, Tingting Sun, Aibin Huang, Lianjun Wang, Wan Jiang, Qihao Zhang.  (2023)  Exceptional n-type thermoelectric ionogels enabled by metal coordination and ion-selective association.  Science Advances,  (43):   [PMID:37878706] [10.1126/sciadv.adk2098]
2. Congsu Niu, Lianyuan Ji, Yao Chen, Shuai Ma, Yiwei Zhang, Xiaomin Liu, Hui Yang.  (2021)  Low-Melting-Point Ionic Liquid Electrolyte for an Intermediate-Temperature Sodium–Copper Chloride Battery.  ENERGY & FUELS,  35  (15): (12538–12545).  [PMID:] [10.1021/acs.energyfuels.1c00833]

References

1. Wei Zhao, Yiwei Zheng, Meng Jiang, Tingting Sun, Aibin Huang, Lianjun Wang, Wan Jiang, Qihao Zhang.  (2023)  Exceptional n-type thermoelectric ionogels enabled by metal coordination and ion-selective association.  Science Advances,  (43):   [PMID:37878706] [10.1126/sciadv.adk2098]
2. Congsu Niu, Lianyuan Ji, Yao Chen, Shuai Ma, Yiwei Zhang, Xiaomin Liu, Hui Yang.  (2021)  Low-Melting-Point Ionic Liquid Electrolyte for an Intermediate-Temperature Sodium–Copper Chloride Battery.  ENERGY & FUELS,  35  (15): (12538–12545).  [PMID:] [10.1021/acs.energyfuels.1c00833]

Solution Calculators